Lake Country Mountain Retreat Design
Technical Performance
Airtightness 0.8 ACH @ 50Pa
Heating Demand 38 kWh/m²a
Energy Source All Electric
Heating & Cooling - Fujitsu Air Source Heat Pump
Supplementary Heating - Wood Stove
Ventilation - ERV - 84% Efficient
Hot Water - Electric Tank
Building Envelope R34 Exterior Walls
R33 Foundation Walls
R68 Roof
R16 Slab on Grade
R51 Cantilevered Floor
Triple Glazed Windows